Power Calc PaK: the automatic calculations

See Video 1.1: Why use Power Calc PaK? 

 

This is what Power Calc PaK automatically calculates and re-calculates for you…

  • Electrical Characteristics of the Panelboard (Main Distribution, Distribution, and Branch Circuit Panelboards). Power Calc PaK automatically calculates, and re-calculates for all changes, the electrical characteristics of the Panelboard including: main feeder conductor and conduit size, Panelboard ampacity, Panelboard overcurrent protection device (OCPD), main feeder voltage drop, and ground conductor electrode.

  • Electrical Characteristics of the Branch Circuits. Power Calc PaK automatically calculates, and re-calculates for all changes, the electrical characteristics of all branch circuits including: branch circuit conductor and conduit size, branch circuit ampacity, branch circuit overcurrent protection device (OCPD), and branch circuit voltage drop, and branch circuit ground conductor.

  • Electrical Characteristics of Building Equipment. Power Calc PaK automatically calculates, and re-calculates for all changes, the electrical characteristics of the building equipment including: electrical characteristics of the branch circuits (paragraph above), size of the overcurrent protection device (OCPD) (fuse or circuit breaker), conductor size, and the electrical enclosure frame size and characteristics.

  • Power Calc PaK automatically calculates, and re-calculates for all changes, the following:

»  Size of Electrical Service

» Panelboard Frame Ampacity for both Copper (CU) and Aluminum (AL) Bus

» Panelboard Mains Rating

»  Building equipment: calculates the electrical requirements including HVAC equipment, compressors, elevators, escalators, and all other electrical equipment.

»  Overcurrent protection device (OCPD)

»  Conductor size: main feeder, branch feeder, and branch circuit

»  Conduit size: main feeder, branch feeder and branch circuit(s)

»  Ground conductor electrode(s) and equipment ground conductor(s

»  Conductor Heat Losses

»  Energy Savings

»   % Voltage Drop (%VD): on main feeder(s), branch feeder, and branch circuit conductor(s)

»  Load Summary Table by the following load type(s): air conditioning (AC), heating (H), lighting (L), motor (M), power (P), receptacle (R), spare (S), site lighting (SL), exterior lighting (XL), transformer (XFMR), and Panelboard (PNL)

»  Load Demand Factor: NEC demand factor(s) and User demand factor(s)

»  Single or multiple parallel main feeders, branch feeders, and branch circuit

»  Transformer including Primary and Secondary Feeder

»  Connected and Demand Electrical Loads