Inputs/Outputs
See Video 1.1: Why use Power Calc PaK?
Power Calc PaK is smart software with a proprietary database that automatically calculates, and re-calculates for all changes, the entire power distribution system in a building from the branch circuit to the electrical service…for any size building, and for multiple buildings like a campus.
Input only 3 values and Power Calc PaK automatically calculates, and re-calculates for all changes, the entire power distribution system.
Power Calc PaK: Input only 3 values = 300 outputs in compliance with the 2011 NEC and other electrical standards.
|
INPUTS:

- Electrical Load kVA
- Type of Electrical Load
- Circuit Breaker # of Poles
|
OUTPUTS:

- Branch Circuit Conductor Size
- Branch Circuit Breaker Trip Amps
- Branch Circuit Ground Conductor Size
- Branch Circuit Conduit Size
- Branch Circuit %Voltage Drop (%VD)
- Branch Circuit Maximum Length of Conductor
- Conductor Length Required to Maintain %VD
- Step Down
- Transformer (kVA)
- Step Down Transformer Primary Feeder Size
- Step Down Transformer Secondary Feeder Size
- Load Tabulation by Type of Electrical Load (Lighting, Motors, Receptacles, etc.)
- Connected Load
- Demand Load - Industry Default Factors
- User input Demand Load Factors
- Panelboard Frame Size (Amps)
- Panelboard Mains Rating (Amps)
- Panelboard Main Feeder Conductor Size
- Panelboard Main Feeder Conduit Size
- Panelboard Multiple Feeders Run in Parallel
- Branch Feeder Temp Correction Factor
- Branch Circuit Temp Correction Factor
- Analysis Notes (Tracks User Input)
- Branch Circuit Multiple Runs in Parallel
- Energy Reduction and Saving Electricity
- Branch Circuit Running Amps
- Branch Feeder Running Amps
- Ground Conductor Size Increase at the Same Ratio of Increasing Branch Circuit Conductors or Feeder Branch Conductors
- Motor Circuits OCPD (Breaker, Fuse)
- Motor Circuits FLA
- Motor Circuits Branch Circuit Size (Wire and Conduit)
- Motor Circuits Ground Conductor Size
- Motor Circuits Disconnect Frame Size
- Motor Circuits Enclosed Circuit Breaker Size
|
ADDITIONAL FEATURES:

User can select the
following features from Power Calc PaK’s proprietary database.
- Mounting Method
- Interrupting Ratings
- AIC Ratings
- Single & Three Phase
- Panelboard(s)
- Utilization Voltage
- Panelboard Bus Material
- Main Circuit Breaker Options
- TVSS
- NEMA Designation
- Isolated Ground
- Neutral Conductor Rating
- 1, 2, or 3 Pole Branch Circuit Breaker
- Analysis Notes for Project Design
- Branch Circuits Multiple Conductor
- Runs in Parallel
|
|