| IEEE 141 |
Recommended Practice for Electric Power Distribution for Industrial Plants |
| |
|
| NEC Article 110 |
Requirements for Electrical Installations |
| NEC 110.4 |
Voltages |
| NEC 110.6 |
Conductor Sizes |
| NEC 110.9 |
Interrupting Rating |
| |
|
| NEC Articles 210 |
Branch Circuits |
| NEC 210.3 |
Rating |
| NEC 210.4 |
Multiwire Branch Circuits |
| NEC 210.8 |
Ground-Fault Circuit–Interrupter Protection for Personnel |
| NEC 210.10 |
Ungrounded Conductors Tapped from Grounded Systems |
| NEC 210.12 |
Arc-Fault Current-Interrupter Protection |
| NEC 210.19 |
Conductors - Minimum Ampacity and Size |
| NEC 210.20 (A) |
|
| |
|
| NEC Article 215 |
Feeders |
| NEC 215.2 |
Minimum Rating and Size |
| NEC 215.2 A (3) |
Minimum Rating and Size: Individual Dwelling Unit or Mobile Home Conductors |
| NEC 215.3 |
Overcurrent Protection |
| NEC 215.4 |
Feeders with Common Neutral Conductor |
| NEC 215.5 |
Diagrams of Feeders |
| NEC 215.9 |
Ground-Fault Circuit-Interrupter Protection for Personnel |
| NEC 215.10 |
Ground-Fault Protection of Equipment |
| |
|
| NEC Article 220 |
Branch-Circuit, Feeder, and Service Calculations |
| NEC 220.5 |
Calculations |
| NEC 220.12 |
Lighting Load for Specified Occupancies |
| NEC 220.14 |
Other Loads-All Occupancies |
| NEC 220.16 |
Loads for Additions to Existing Installations |
| NEC 220.18 |
Maximum Loads |
| NEC 220.40 |
Feeder and Service Load Calculations: General |
| NEC 220.42 |
General Lighting |
| NEC 220.43 |
Show-Window and Track Lighting |
| NEC 220.44 |
Receptacle Loads-Other Than Dwelling Units |
| NEC 220.50 |
Motors |
| NEC 220.51 |
Fixed Electric Space Heating |
| NEC 220.52 |
Small-Appliance and Laundry-Loads Dwelling Unit |
| NEC 220.53 |
Appliance Load-Dwelling Unit(s) |
| NEC 220.54 |
Electric Clothes Dryers-Dwelling Unit(s) |
| NEC 220.55 |
Electric Ranges and Other Cooking Appliances-Dwelling Unit(s) |
| NEC 220.56 |
Kitchen Equipment-Other Than Dwelling Unit(s) |
| NEC 220.60 |
Noncoincident Loads |
| NEC 220.61 |
Feeder or Service Neutral Load |
| NEC Table 220.84 |
Optional Calculations – Demand Factors for Three or More Multifamily Dwelling Units |
| |
|
| NEC Article 225 |
Outside Branch Circuits and Feeders |
| NEC 225.36 |
Suitable for Service Equipment |
| |
|
| NEC Article 230 |
Services |
| NEC 230.23 |
Size and Rating |
| NEC 230.31 |
Size and Rating |
| NEC 230.42 |
Minimum Size and Rating |
| NEC 230.79 |
Rating of Service Disconnecting Means |
| NEC 230.90 |
Service Equipment – Overcurrent Protection: Where Required |
| NEC 230.95 |
Ground-Fault Protection of Equipment |
| |
|
| NEC Article 240 |
Overcurrent Protection |
| NEC 240.4 |
Protection of Conductors |
| NEC 240.6 |
Standard Ampere Ratings |
| NEC 240.13 |
Ground-Fault Protection of Equipment |
| NEC 240.15 |
Ungrounded Conductors |
| NEC 240.21 |
Location in Circuit |
| NEC 240.23 |
Change in Size of Grounded Conductor |
| NEC 240.30 |
Enclosures: General |
| NEC 240.60 |
Cartridge Fuses and Fuseholders: General |
| NEC 240.92 |
Location in Circuit |
| |
|
| NEC Article 250 |
Grounding and Bonding |
| NEC 250.30 |
Grounding Separately Derived Alternating-Current Systems |
| NEC 250.30 (B)(1) |
Grounding Electrode Conductor |
| NEC 250.52 |
Grounding Electrodes |
| NEC 250.66 |
Size of Alternating-Current Grounding Electrode Conductor |
| NEC Table 250.66 |
Grounding Electrode Conductor for Alternating-Current Systems |
| NEC 250.122 |
Size of Equipment Grounding Conductors |
| NEC 250.122(B) |
Increased in Size |
| NEC 250.122(C) |
Multiple Circuits |
| NEC 250.122 (D) |
Motor Circuits |
| NEC 250.122 (F) |
Conductors in Parallel |
| NEC 250.122 (G) |
Feeder Taps |
| NEC Table 250.122 |
Minimum Size Equipment Grounding Conductors for Grounding Conductors for Grounding Raceway and Equipment |
| |
|
| NEC Article 285 |
Surge Protective Devices (SPDs), 1kV or Less |
| |
|
| NEC Article 300 |
Wiring Methods |
| NEC 300.1(C) |
Metric Designators and Trade Sizes |
| |
|
| NEC Article 310 |
Conductors for General Wiring |
| NEC 310.4 |
Conductors in Parallel |
| NEC 310.10 |
Temperature Limitation of Conductors |
| NEC 310.15 |
Ampacities for Conductors Rated 0-2000 Volts |
| NEC 310.15(B)(2) |
Ampacities for Conductors rated 0-200 Volts: Panelboard Neutral Conductor Size: Adjustment Factors |
| NEC Table 310.15(B)(2)(a) |
Adjustment Factors for More than Three Current-Carrying Conductors in a Raceway |
| NEC Table 310.15(B)(6) |
Conductor Types and Sizes for 120/240-Volt, 3-Wire, Single-Phase Dwelling Services and Feeders |
| NEC Table 310.16 |
Allowable Ampacities of Insulated Conductors Rated 0 Through 2000 Volts, Correction Factors |
| NEC 310.60 |
Conductors Rated 2001 - 35,000 Volts |
| |
|
| NEC Article 312 |
Cabinets, Cutout Boxes, and Meter Socket Enclosures |
| NEC 312.2 |
Damp or Wet Locations |
| |
|
| NEC Article 344 |
Rigid Metal Conduit: Type RMC |
| NEC 344.22 |
Number of Conductors |
| |
|
| NEC Article 408 |
Switchboards and Panelboards |
| NEC 408.3(C) |
Used as Service Equipment |
| NEC 408.3(E) |
Phase Arrangement |
| NEC 408.3(F) |
High Leg Identification |
| NEC 408.4 |
Circuit Directory or Circuit Identification |
| NEC 408.14 |
Maximum Number of Overcurrent Devices (Prior to NEC 2008) |
| NEC 408.30 |
|
| NEC 408.36 |
Overcurrent Protection |
| NEC 408.37 |
Panelboards in Damp or Wet Location |
| NEC 408.40 |
Grounding of Panelboards |
| NEC 408.54 |
Maximum Number of Overcurrent Devices |
| |
|
| NEC Article 422 |
Appliances |
| NEC 422.1 |
Scope |
| NEC 422.11 |
Overcurrent Protection |
| NEC 422.52 |
Electric Drinking Fountains |
| |
|
| NEC Article 430 |
Motors, Motors Circuits, and Controllers |
| NEC 430.21 |
Motors Circuit Conductors: General |
| NEC 430.22 |
Single Motor |
| NEC 430.24 |
Several Motors or a Motor(s) and Other Load(s) |
| NEC 430.25 |
Multimotor and Combination-Load Equipment |
| NEC 430.31 |
Motors and Branch-Circuit Overload Protection: General |
| NEC 430.42 |
Motors on General-Purpose Branch Circuits |
| NEC 430.52 |
Rating or Setting for Individual Motor Circuit |
| NEC Table 430.52 |
Maximum Rating or Setting of Motor, Branch-Circuit Short-Circuit and Ground-Fault Protective Devices |
| NEC 430.53 |
Several Motors or Loads on One Branch Circuit |
| NEC 430.54 |
Multimotor and Combination – Load Equipment |
| NEC 430.62 |
Rating or Setting-Motor Load |
| NEC 430.92 |
Motor Control Centers: General |
| NEC Table 430.248 |
Full-Load Currents in Amperes, Single-Phase Alternating-Current Motors |
| NEC Table 430.249 |
Full-Load Current, Two-Phase Alternating-Current Motors (4-Wire) |
| NEC Table 430.250 |
Full-Load Current, Three-Phase Alternating-Current Motors |
| |
|
| NEC Article 440 |
Air-Conditioning and Refrigerating Equipment |
| NEC 440.6 |
Ampacity and Rating |
| NEC 440.11 |
Disconnecting Means: General |
| NEC 440.12 |
Rating and Interrupting Capacity |
| NEC 440.22 |
Branch-Circuit Short-Circuit and Ground-Fault Protection: Application and Selection |
| |
|
| NEC Article 695 |
Fire Pumps |
| |
|
| NEC Article 700 |
Emergency Systems |